Ultra Trace Labs


Ultra Trace Pty Ltd
58 Sorbonne Crescent Canning Vale Western Australia 5155
Phone (08) 9455 0404 Fax (08) 9455 0403


Reference : u53175
Date : 19th August 2004
Order
Project
Date Received : 10th May 2004
Samples Analysed : 10

Analysis of Solutions for Sutton's Colloidal Solutions

15 Goldney Court
Leda 6170
W. A.
Attention : Mr G Franklin
Authorised by : V Eldridge
Reference u53175

  Ag
mg/1
Ca
mg/1
K
mg/1
MG
mg/1
SI
mg/1
pH
mg/1
             
Detn Limit 0.1 0.1 0.5 0.1 0.2 0.1
             
23/02/04 Batch 14 17.0 <0.1 <0.5 <0.1 0.2 8.9
24/02/04 Batch 15 13.5 0.1 0.5 <0.1 0.2 9.0
03/03/04 Batch 16 18.1 <0.1 1.0 <0.1 0.2 9.6
08/03/04 Batch 17 17.6 <0.1 0.5 <0.1 0.2 9.6
19/03/04 Batch 18 17.5 0.1 <0.5 <0.1 0.2 9.6
24/03/04 Batch 19 18.8 0.1 <0.5 <0.1 0.2 9.5
30/03/04 Batch 20 17.1 0.1 <0.5 <0.1 0.2 9.6
15/04/04 Batch 21 16.8 <0.1 <0.5 <0.1 0.2 9.5
15/04/04 Batch 21 Rpt 16.7 0.1 <0.5

<0.1

0.2 9.5
18/04/04 Batch 22 18.6 <0.1 0.5 <0.1 0.2 8.8
20/04/04 Batch 23 16.8 0.1 0.5 <0.1 0.2 9.5
20/04/04 Batch 23 Rpt 16.7 <0.1 <0.5 <0.1 0.2 9.5
             
Std Nominal            
Determined 2035 0.1 <0.5 <0.1 <0.2  
             
Std Nominal   100.0 130.0 100.0 6.0  
Determined

<0.1

101.0 143.0 99.4 5.8  
             
Std Nominal   37.5 16.0 24.4 9.6  
Determined <0.1 36.6 16.0 23.1 9.0  
             

 

Reference u53175 Order

These results pertain to the samples as received at this laboratory.
Where standards are reported, the nominal value for the element is reported
above the result found.

Sample Preparation
No sample preparation was required on these samples.

The solutions have not been treated other than by dilution.

Mg, Ca, K, Mg, Si
have been determined by Inductively Coupled Plasma (TEP) Optical

pH has been determined by direct measurement with a pH meter.